this post was submitted on 15 Aug 2026
649 points (97.7% liked)
Science Memes
20971 readers
1681 users here now
Welcome to c/science_memes @ Mander.xyz!
A place for majestic STEMLORD peacocking, as well as memes about the realities of working in a lab.

Rules
- Don't throw mud. Behave like an intellectual and remember the human.
- Keep it rooted (on topic).
- No spam.
- Infographics welcome, get schooled.
Research Committee
Other Mander Communities
Science and Research
Biology and Life Sciences
- !abiogenesis@mander.xyz
- !animal-behavior@mander.xyz
- !anthropology@mander.xyz
- !arachnology@mander.xyz
- !balconygardening@slrpnk.net
- !biodiversity@mander.xyz
- !biology@mander.xyz
- !biophysics@mander.xyz
- !botany@mander.xyz
- !ecology@mander.xyz
- !entomology@mander.xyz
- !fermentation@mander.xyz
- !herpetology@mander.xyz
- !houseplants@mander.xyz
- !medicine@mander.xyz
- !microscopy@mander.xyz
- !mycology@mander.xyz
- !nudibranchs@mander.xyz
- !nutrition@mander.xyz
- !palaeoecology@mander.xyz
- !palaeontology@mander.xyz
- !photosynthesis@mander.xyz
- !plantid@mander.xyz
- !plants@mander.xyz
- !reptiles and amphibians@mander.xyz
Physical Sciences
- !astronomy@mander.xyz
- !chemistry@mander.xyz
- !earthscience@mander.xyz
- !geography@mander.xyz
- !geospatial@mander.xyz
- !nuclear@mander.xyz
- !physics@mander.xyz
- !quantum-computing@mander.xyz
- !spectroscopy@mander.xyz
Humanities and Social Sciences
Practical and Applied Sciences
- !exercise-and sports-science@mander.xyz
- !gardening@mander.xyz
- !self sufficiency@mander.xyz
- !soilscience@slrpnk.net
- !terrariums@mander.xyz
- !timelapse@mander.xyz
Memes
Miscellaneous
founded 3 years ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
Would that only happen if one outlet were wired backwards (hot to neutral and vice-versa)?
If both outlets are wired correctly, as I'm envisioning it, the extension cord is parallel to the existing branch.
Same if both outlets are wired (the same) incorrectly.
But if one outlet is wired correctly and one has its poles swapped, then you are shorting hot directly to neutral...
But also being a 3-prong outlet...assuming everything is wired correctly...the short would either be redirected to ground and either trip the breaker or trigger a GFCI...no?
IANAElectrician. Just a high dude thinking about circuits.
Worth mentioning that the point of a suicide cord like this isn't to connect two outlets together...really no reason to do that...it's usually used to hook up a generator (or other load-center, like say a campground plug) to a branch circuit when the home/rv/load doesn't have an inlet. It's also extremely dangerous if used incorrectly, and there are several ways to very easily use it incorrectly.
You can't just branch and reconnect AC power lines at random points.
Or rather, you can, maybe only once though.
In a residential setting with reasonable extension cable length & gauge, and reasonable loads you actually kinda can. Impedance and phase mismatches won't matter on those scales. In fact, that's basically what a ring circuit is.
Anecdote: my grandparents basically had an "accidental ring circuit" in their old house for like 40 years. It was only noticed when they hired an electrician to upgrade the wiring for an electric stove