Seefoo

joined 2 years ago
[–] Seefoo@lemmy.world 2 points 2 weeks ago

spoilerwell, in the talking scene, you get a slow motion at the end and can shoot him with your pistol. at witch point you carry her the rest of the way and later on she sends you a memento from the moon telling you she's doing well now. If you can't redo, I would go watch it on youtube at least so you can see your ending.

[–] Seefoo@lemmy.world 2 points 2 weeks ago* (last edited 2 weeks ago) (2 children)

Tap for spoilerYou can definitely kill reed and send her off on the shuttle. Not sure what happened on your run.

[–] Seefoo@lemmy.world 1 points 2 weeks ago

I like lens feature a lot. I also use their privacy pass feature quite a bit. Overall there are a lot of really nice features and search results as good or better than Google. DDG uses bing which is junk IMO

[–] Seefoo@lemmy.world 3 points 2 weeks ago (5 children)
[–] Seefoo@lemmy.world 7 points 4 weeks ago

Little Rocket Lab - fun factory builder with Stardew valley vibes

[–] Seefoo@lemmy.world 8 points 2 months ago

You can do a reverse proxy + authelia (or other auth service). It's still more risky than a VPN IMO, buts wayyyy better than some of the other options in this thread

[–] Seefoo@lemmy.world 3 points 2 months ago

I have been for over a year now. I love it personally got my mom and wife on it too

[–] Seefoo@lemmy.world 8 points 2 months ago

Plex clients arent great, but they are better on many TVs compared to jellyfin. Also the wife is used to it, so I don't really want to retrain

[–] Seefoo@lemmy.world 22 points 2 months ago* (last edited 2 months ago) (5 children)

Yea, if you romance Judy instead of panama and pick the Aldecaldos, she leaves with you. It's probably already the most positive ending for V

[–] Seefoo@lemmy.world 2 points 4 months ago

I haven't looked into the config details too much, but I think its audible. I did see some hardcover & goodreads related code when perusing some of the docs, but didn't really look much deeper.

[–] Seefoo@lemmy.world 4 points 4 months ago

this feels like a harsh characterization. Their description of AI usage is exactly what I would want in a project using AI. I haven't looked at their actual practices, so I guess I am trusting on that side. All that said, this is similar to my workflow at work, so I am not as negative on it.

 

Just a PSA. I didn't see any posts on here about it, but have really been enjoying it and the wife likes it a lot. It solved a lot of manual effort on my part for getting audiobooks into Audiobookshelf w/o much manual intervention. The request system is similar to *seerr and its pretty simple to setup. Bonus: it supports OIDC out of the box, which I appreciate so I dont have one more account to manage.

[–] Seefoo@lemmy.world 3 points 4 months ago

This guys been waiting for his moment

39
submitted 11 months ago* (last edited 11 months ago) by Seefoo@lemmy.world to c/homeimprovement@lemmy.world
 

I am installing smart switches in my home. I have this 2-gang box at the top of our stairs, where I am doing a virtual 3-way setup for both switches. One powers the light on the stairs, the other the hallway at the top of the stairs. A few things:

  • This box has no live wires since its the other side of the two 3-ways (I have tested this by disconnecting all wires from all switches and checking for lives).
  • Each of the boxes is on a separate breaker. It has TWO sets of neutral pigtails in the back. This is the correct setup, but its possible the neutrals where mixed up during the original wiring of the house.
  • Each set of romex wires is connected to another set of romex. None of them criss-cross (except the grounds).

Now, here is my odd behavior and my need for assistance:

After wiring the two virtual 3-way setups (Option 2 from this page) everything was working fine. I was also planning to switch out the fixtures, so I went back and turned off the breaker for the hallway, but the smart switch for the hallway was still active (LED is on, I can see it on homeassistant). Now, I am thinking the original wiring mixed up the loads in the box with the incoming wires and the two neutrals for those breakers have been connected...anyone have thoughts on whats going on? is the solution here to basically swap the incoming 3-wire load romex?

**Solution: ** I am not 100% certain the cause of the issue. It is possible I mixed the wiring up when doing the virtual 3-way, but I basically followed the advice here and started from scratch. I traced the travelers from each of the main boxes and connected them to the appropriate load and completed disconnected the 3-way part. once I had the right load on the right travelers, I then setup the virtual switches wiring off the black wire coming with the traveler. Lastly, I ensured the neutrals from the two romexs that had a traveler+load where pigtailed with the virtual switch. took a bit of time, but felt this was the easiest way to not spin my wheels too much. Appreciate the advice, if anyone really does want, I can put together a diagram (on paper 😉 )

view more: next ›