view the rest of the comments
politics
Welcome to the discussion of US Politics!
Rules:
- Post only links to articles. Title must fairly describe link contents. If your title differs from the site’s, it should only be to add context or be more descriptive. Do not post entire articles in the body or in the comments.
Links must be to the original source, not an aggregator like Google Amp, MSN, or Yahoo.
Example:

- Articles must be relevant to US politics and contain quality and original content. Social Media adjacent hosts like Substack are allowed, but ONLY if they tie back to a company/subsidiary. No personal or friend group blogs and no self-promotion. Articles should be worth reading. Clickbait, stub articles, and re-hosted or stolen content are not allowed. Check your source for Reliability and Bias here.
- Be civil, No violations of TOS. It’s OK to say the subject of an article is behaving like a (pejorative, pejorative). It’s NOT OK to say another USER is (pejorative). Strong language is fine, just not directed at other members. Engage in good-faith and with respect! This includes accusing other users of being bots or paid actors.
- No memes, trolling, misinformation, or low-effort posts/comments (including reposts). If you see posts like this that anger you, do not engage. Report, block, and live a happier life than they do. Any slap-fight is subject to comment removals. Fights full of rule violations will result in temporary bans to cool off.
- No manipulating votes via bots or alt accounts; this will result in permanent bans. Vote based on comment quality, not agreement. This community aims to foster discussion; please reward people for putting effort into articulating their viewpoint, even if you disagree with it.
- No hate speech, slurs, celebrating death, advocating violence, or abusive language. This will result in an account ban. Usernames containing racist, or inappropriate slurs will be permanently banned.
We ask that the users report any comment or post that violate the rules and use critical thinking when reading, posting, and commenting. Users that repeatedly have comments or posts removed, weaponize reports, or violate the code of conduct, will be banned.
All posts and comments will be reviewed on a case-by-case basis. This means that some content that violates the rules may be allowed, while other content that does not violate the rules may be removed. The moderators retain the right to remove any content and ban users. The reason(s) behind moderator action(s) are publicly available through the Modlog.
That's all the rules!
Civic Links
• Congressional Awards Program
• Library of Congress Legislative Resources
• U.S. House of Representatives
Partnered Communities:
• News
I work at a datacenter that uses around 2 bathtubs of water per month - almost none in the winter and weather dependent in summer. In my opinion not much. The closed loop sends water from the computers up to the roof where it trickles down a series of radiators to cool then flows back inside. Some is lost due to evaporation but it is very efficient. For most of the year we are just blasting in air from outside but the water chillers kick in when the outside temp reaches 23C.
Though sadly they are not building datacenters like this anymore because it's more reliable and cheaper to just use water and discard it. I believe we went this way because power is all hydro here and very cheap.
The electricity generation uses much, much more (on average)
Is the DC you work more for storage or is it high compute like DCs for LLMs? I'm just curious how the size and heat generation would compare if it's not.
It's a datacenter used primarily for research computing and education. Internet Archives even pays rent on a rack hosted here.
It used to be the latter but it's becoming the former. We recently had to add many new chillers as we deploy high compute nodes.
Very large increase in power demand but in my location the power grid is way bigger than the load and we sell power to the states that we don't use anyway.
Many new nodes are coming online due to the square kilometer array project: https://en.wikipedia.org/wiki/Square_Kilometre_Array
We had to take out some trees and build a tall wall so the neighbours can't hear it which kind of sucks. Nobody has complained but we preemptively built the wall due to bad press over noise complaints circulating the media right now I think.
I have to say the environment inside the data room has become a lot more hostile to work in since we turned on so many high compute nodes. It's very loud and one of the hot aisles is around 42C. I can only imagine the traces of metal bearings I have in my lungs.
Basically though I think it's impossible to deploy a hyper datacenter with the same cooling system we use in 2026. At such mass scale there is no way you could source enough chillers in such short amount of time. After covid it's been hard to get things like this. It's very specialized equipment.
So that's why they are trying to deploy them in the middle of nowhere where you can just steal the water and therefor the cooling system is very simple.
And if we want to get into conspiracies I think this is the real reason that the US administration is so interested in Greenland and Canada. China is close to deploying a quantum computer and whoever does that first will be the new world power without any doubt.
Yeah you’re in what I’d refer to as a “traditional” DC. Power per rack in those facilities are about 16kW give or take. Hyperscale AI DCs use about 80-100kW per rack. It’s astonishing that it’s an almost 8x increase in power (and thus water) and they’re cheaping out and not wanting to build closed loop, so you can only imagine what that hot aisle is like.