[-] njordomir@lemmy.world 1 points 2 hours ago

I've been to Phantasialand. It was a nice park.

I have to agree with the other commenters. I feel like this is a task for a loudly audible alarm system and maybe a flashing strobe in the operators office, not an email.

[-] some_kind_of_guy@lemmy.world 32 points 10 hours ago

Subject: Fire.

Dear Sir/Madam,

~~I am writing to inform you of a fire that has broken out on the premises of 123 Cavendon Road.~~

Fire! Fire! Help me!

123 Cavendon Road. Looking forward to hearing from you.

Yours truly,
Maurice Moss

[-] jj4211@lemmy.world 4 points 8 hours ago

A fire? At a sea parks?!

[-] MajorasTerribleFate@lemmy.zip 6 points 10 hours ago

I know he tried calling 0118 999 881 999 119 725 3 first, but had he not ended up with another country on the line it would have been a much quicker response.

[-] Blackmist@feddit.uk 6 points 11 hours ago
[-] Wildmimic@anarchist.nexus 83 points 18 hours ago* (last edited 17 hours ago)

The technical standards for Email would allow for 3 days of delivery failure before finally giving up. That's the amount of leeway email has (in theory - practically we assume that everything longer than 3 minutes means something has gone wrong). Sending alerts by email is fine for non-critical applications; if one of my docker containers crash, an email is fine because the amount of damage is nil.

Why wasn't there an actual fail-safe mechanism employed that measures the chlorine levels and shuts the whole thing down BEFORE it gets dangerous?

This is not a Microsoft problem. This is a negligence problem on Phantasialands side, using inappropiate tools for a system that can hurt people on failure, and should be followed up by lawsuits.

[-] Agent641@lemmy.world 11 points 12 hours ago

From: noreply@carbondioxidedetector.com.au

RE: Carbon Dioxide leak detected

Message: To whom it may concern, an elevated carbon dioxide level was measured in the walk-in fridge in the bar kitchen. Probably one of the keg lines is leaking pressurised gas. Gas PPM is classified as alert level 5 - Immediately harmful to life. Please evacuate staff from the area and ventilate the fridge thoroughly before attempting entry with ELSRD hood donned to shut down gas flow.

Folder: Spam

[-] panda_abyss@lemmy.ca 4 points 9 hours ago

Yeah

“Why do all our alerts go to spam”

Oh, well everyone just ignores them, then Jeff who isn’t even on the IT team but was on the mailing list was getting them. So Jeff marked them as spam instead of asking to be removed from the mail list, and now our corporate email provider just black holes them.

[-] VAK@lemmy.world 9 points 12 hours ago

Why the fuck would you open the pool without getting a mail saying it is safe?

[-] cy888@lemmy.world 9 points 12 hours ago

The email is that there is a dangerous condition, not that it is safe.

[-] JcbAzPx@lemmy.world 3 points 10 hours ago

I'm thinking maybe that should be the other way around.

[-] Reygle@lemmy.world 5 points 11 hours ago

GTFO of the cloud, you idiot humans

[-] thespcicifcocean@lemmy.world 14 points 13 hours ago

What the fuck?

[-] GreenKnight23@lemmy.world 12 points 13 hours ago

Germans gassing people

2026

did not expect that on my bingo card.

[-] tyrefyre@sh.itjust.works 2 points 7 hours ago

Those who do not study history are doomed to repeat it.

[-] Axolotl_cpp@lemmy.dbzer0.com 60 points 20 hours ago* (last edited 20 hours ago)

Yeaaah not MS fault here, no sane person would rely solely on email for something like this

load more comments (24 replies)
[-] absGeekNZ 23 points 17 hours ago

Industrial automaton engineer here, I've worked on a bunch of safety critical systems and audited systems after incidents.

Best practice in situations were you are sending a remote start command, is for the stop command to be local to the pump controller.

I audited a system where the main control system sheet a start command to the dosing shed (which stored the concentrated chemicals), unfortunately the stop command was over the same link that got interrupted. The start was received but the stop was never was. Radio is not a reliable link.

For chemical dosing, I'd expect at least two types of command signals, such as concentration and Max allowed time; you could also measure the weight loss of the concentrate as a third check. Loss of communications to the main controller isn't necessity an instant stop, but I would expect a prolonged loss to trigger a stop. As long as the local controller has stop control, dosing can usually continue.

[-] noxypaws@pawb.social 1 points 9 hours ago

mff 2014 ass bullshit

[-] Kazel@lemmy.dbzer0.com 48 points 21 hours ago

fuck microslop but that one is 100% on Phantasialand

[-] razen@lemmy.world 13 points 17 hours ago

This isn't MS fault, what happened to Normal Alarming System

[-] zedgeist@lemmy.zip 1 points 11 hours ago

Don't be so NASty

[-] beejjorgensen@lemmy.sdf.org 411 points 1 day ago

No mails arrived due to the disruption [...]. So no one noticed that the maintenance safety system of the sauna landscape has long since sounded the alarm by mail. Because the automatic dosing system had pumped too much chlorine into the pool.

Kinda scary to rely solely on email for such alarms.

[-] Fmstrat@lemmy.world 4 points 10 hours ago

100%. This is not because of an outage, this is because whoever set this up is an idiot.

[-] lornosaj@lemmy.world 17 points 20 hours ago

In proper SRE, there is a rule - mails are not alerts and must not be used as such.

[-] Remember_the_tooth@lemmy.world 220 points 1 day ago

Yeah, I hate Microsoft as much as the next person, but this is 100% on Phantasialand for trying to cut corners with excessive automation.

[-] Schemen110676@lemmy.ml 16 points 19 hours ago

No.. with the wrong kind of automation.

Safety relevant systems do not belong on public infrastructure

load more comments (1 replies)
[-] 2ndDegreeOWO@lemmy.world 95 points 1 day ago

It's not excessive automation -- it's a lack of redundancy for critical safety features.

Anything safety-critical should never have a single point of failure if you can help it. And there was definitely an opportunity here to have some kind of secondary backup alarm system.

[-] Schemen110676@lemmy.ml 10 points 19 hours ago

On top of that it should fail safely.. and not simply stop working without anyone knowing

load more comments (1 replies)
load more comments (9 replies)
load more comments (2 replies)
load more comments
view more: next ›
this post was submitted on 15 Nov 2026
576 points (98.2% liked)

Technology

89814 readers
4034 users here now

This is a most excellent place for technology news and articles.


Our Rules


  1. Follow the lemmy.world rules.
  2. Only tech related news or articles.
  3. Be excellent to each other!
  4. Mod approved content bots can post up to 10 articles per day.
  5. Threads asking for personal tech support may be deleted.
  6. Politics threads may be removed.
  7. No memes allowed as posts, OK to post as comments.
  8. Only approved bots from the list below, this includes using AI responses and summaries. To ask if your bot can be added please contact a mod.
  9. Check for duplicates before posting, duplicates may be removed
  10. Accounts 7 days and younger will have their posts automatically removed.

Approved Bots


founded 3 years ago
MODERATORS