[–] kersploosh@sh.itjust.works 123 points 1 day ago (4 children)

The last extension cord you will ever need.

[–] JasonDJ@lemmy.zip 3 points 11 hours ago (2 children)

The lovely suicide cord.

Worth mentioning that it is plenty safe...if used appropriately (for attaching a generator to a house that doesn't have an inlet).

It's when it's not used appropriately that's a problem. And it's very easy to not use it appropriately.

[–] thetrekkersparky@startrek.website 6 points 11 hours ago (1 children)

Worth mentioning that they are absolutely not safe as the exposed prongs are energised. They are called suicide cords for a reason. All it takes is to plug the cord into a running generator or working outlet first and the exposed terminals are now live.

Its also worth noting that they very often kill linesmen working to desire the utility because people use them to hook up their generators without turning off their main breaker which back feeds onto the grid.

Proper generator inlets are very readily available and if you don't want to go that route, just plug your fridge and other important devices into your generator with extension cords.

[–] JasonDJ@lemmy.zip 1 points 11 hours ago (1 children)

And that would all count as "not using it correctly".

As I said, they are many ways to very easily use it incorrectly. Being overconfident about it is one, which is why I have an inlet and an interlock.

There are zero ways to use this cord correctly. Do not tell people otherwise. The proper generator connection is to, as you just said, use a proper generator inlet and interlock like you said you use. Anyone using a cord like this is using it incorrectly as there is no correct way to use it. Both the CEC and the NEC expressly forbid these. All it takes is for a child to unplug the wrong end and touch the exposed prongs and they will get shocked.

A proper generator inlet should have the male ends in a recessed inlet box connected to either a transfer switch or an interlocked generator panel.

[–] Bad_Ideas_In_Bulk@lemmy.world 4 points 10 hours ago* (last edited 10 hours ago) (1 children)

Murphy's law says it will be used wrong, and as such it is a bad design and a bad idea.

There are alternatives that are better, this has only the advantage of being cheap.

[–] JasonDJ@lemmy.zip 1 points 9 hours ago (1 children)

It has the advantage of being easily made in an emergency situation.

Idk, I think it's a worthwhile thought exercise to know the wrong ways to do something, in case the situation ever arises where you need to.

[–] Bad_Ideas_In_Bulk@lemmy.world 1 points 7 hours ago

To a certain extent, yes.

Like it's a good idea to drink from a ditch if that's the only water. Better than dying of thirst anyway.

[–] lime@feddit.nu 34 points 1 day ago (7 children)

at least it's short enough that it will only reach two plugs on the same panel, thereby guaranteeing that the first things that blow are breakers.

[–] JasonDJ@lemmy.zip 3 points 11 hours ago* (last edited 11 hours ago) (1 children)

Would that only happen if one outlet were wired backwards (hot to neutral and vice-versa)?

If both outlets are wired correctly, as I'm envisioning it, the extension cord is parallel to the existing branch.

Same if both outlets are wired (the same) incorrectly.

But if one outlet is wired correctly and one has its poles swapped, then you are shorting hot directly to neutral...

But also being a 3-prong outlet...assuming everything is wired correctly...the short would either be redirected to ground and either trip the breaker or trigger a GFCI...no?

IANAElectrician. Just a high dude thinking about circuits.

Worth mentioning that the point of a suicide cord like this isn't to connect two outlets together...really no reason to do that...it's usually used to hook up a generator (or other load-center, like say a campground plug) to a branch circuit when the home/rv/load doesn't have an inlet. It's also extremely dangerous if used incorrectly, and there are several ways to very easily use it incorrectly.

[–] marcos@lemmy.world 1 points 10 hours ago* (last edited 10 hours ago) (1 children)

If both outlets are wired correctly, as I’m envisioning it, the extension cord is parallel to the existing branch.

You can't just branch and reconnect AC power lines at random points.

Or rather, you can, maybe only once though.

[–] balsoft@lemmy.ml 1 points 2 hours ago* (last edited 2 hours ago)

In a residential setting with reasonable extension cable length & gauge, and reasonable loads you actually kinda can. Impedance and phase mismatches won't matter on those scales. In fact, that's basically what a ring circuit is.

Anecdote: my grandparents basically had an "accidental ring circuit" in their old house for like 40 years. It was only noticed when they hired an electrician to upgrade the wiring for an electric stove

[–] SapphironZA@sh.itjust.works 1 points 12 hours ago

You are forgetting the plug on the knob that will plug it in

[–] terranoid@lemmy.cafe 37 points 1 day ago (1 children)

Yeah, not what I need. I need NEMA 5-15 to CAT6 adapter

[–] lime@feddit.nu 44 points 1 day ago

the P in PoE stands for Pulverization

[–] CoopaLoopa@lemmy.dbzer0.com 7 points 1 day ago (2 children)

Unless one of your outlets is wired backwards, plugging this into 2 outlets on the same side of your electrical panel won't do anything.

If you were able to plug it into outlets on different sides of your panel, then you just created a 240v short and the cable is going to be real-spicy real-quick.

[–] whyNotSquirrel@sh.itjust.works 2 points 14 hours ago

then the thermal breaker would jump

[–] marcos@lemmy.world -1 points 10 hours ago (1 children)

plugging this into 2 outlets on the same side of your electrical panel won’t do anything.

That's only true if your house runs on DC.

[–] anomnom@sh.itjust.works 2 points 5 hours ago

Unless the cord crosses hot to neutral, connecting two ends to the same outlet won’t do anything. In fact behind the wall, that’s how the two halves of a socket, or two adjacent sockets on the same breaker, are wired.

[–] Venator 4 points 1 day ago* (last edited 1 day ago)

Unless you accidentally touch one of the prongs after plugging one end in... 😅

[–] _druid@sh.itjust.works 11 points 1 day ago (1 children)

Alternatively, One can plug one end in, then you have a creative new way to parent.

"Didn't mow the lawn? C'mere Billy, hold out your palm."

[–] lime@feddit.nu 9 points 1 day ago (1 children)

i managed to do that to myself once in my sleep; i had managed to wrap my arm around a lamp cord which came out of the plug, and when i rolled over i managed to put my thumb on the exposed wires.

[–] rtxn@lemmy.world 20 points 1 day ago (4 children)

I'll never understand why the US refuses to modernize the horrid NEMA 5 connectors. A recessed receptacle, insulators around the base of the live and neutral blades, spring-loaded detention mechanism to keep the connector from slipping out... in its current state, it's only two steps removed from sticking the bare wires into the socket.

[–] blackberry28@sh.itjust.works 3 points 14 hours ago

Because everything the EU and the rest of the world does is stupid. By adapting things from other countries would be akin to acknowledging that other countries can do some things better than the US. But this can't be, since the US is Numbaaa 1! /s

[–] autriyo@feddit.org 13 points 1 day ago

Tbh insulating the blades bases would be a huge step in the right direction, and there's no remodeling required.

At least for homeowners, factories would need new production lines presumably.

[–] lime@feddit.nu 2 points 20 hours ago

i don't live in north america, but this was in a house from the 1910s.

[–] dohpaz42@lemmy.world 6 points 1 day ago (1 children)
  1. Arrogance: we especially don’t want to do it because the rest of the world does.
  2. Cost: not the equipment, though that can get pretty pricey considering we up the margins on everything, but mostly labor; labor is ungodly expensive (they cry insurance or (my fave) “you’re paying for the years of experience”).
[–] SapphironZA@sh.itjust.works 3 points 11 hours ago
  1. We have gotten use to having regular house fires in houses made of paper.
[–] Lemmyoutofhere@lemmy.ca 3 points 1 day ago

Laughs in generator.

[–] uen3@sh.itjust.works 12 points 1 day ago (1 children)
[–] agamemnonymous@sh.itjust.works 2 points 1 day ago (3 children)

Is this the one you use to feed the house from a generator? If so, I think that's the one time it's valid

[–] dalekcaan@feddit.nl 1 points 8 hours ago* (last edited 8 hours ago) (1 children)

Not legally, and if you're not careful it can go from a suicide cord to a homicide cord. If you're still connected to the grid while you use one, it can backfeed and fry a lineman who was working on what they thought was a disconnect line.

The proper way to do it is to get a transfer switch, which disconnects you from mains before you can connect to a generator.

[–] Buddahriffic@lemmy.world 2 points 8 hours ago (1 children)

Not doubting what you're saying but just a bit confused because wouldn't electrifying what a lineman works on end up overloading the generator because you're now powering everything up to where the circuit broke upstream? Saying this based on an assumption that the lines service multple households and the generators are designed to keep important things running rather than just replace power plants for even one house, let alone the neighbourhood.

How do they handle solar setups that are set up specifically to send power into the grid?

[–] hereiamagain@sh.itjust.works 1 points 2 hours ago

Not an electrician, I always imagined the downed power line being close to the house, such that when you backfeed the transformer it doesn't have a load on it until the lineman grabs it and becomes the load.

I imagine when your circuit that's still connected includes several houses or most of your neighborhood, then maybe you'd overload the generator? 🤷‍♂️ I don't know.

Solar systems I do know, though. If you have a grid-tied solar system, that feeds power back into the grid, then when the power goes out, your batteries and inverters are all turned off automatically so they won't kill linemen. That's what's ironic about grid connected solar, you can't use it during a power outage. They only work when the power is on.

Now if you have a standalone solar system, with a transfer panel where you can switch several circuits in your house to either run on the grid OR solar, then you can use solar whether the grid is up or down. But you can never feed the grid to make money back directly in that fashion.

[–] Duamerthrax@lemmy.world 2 points 11 hours ago* (last edited 7 hours ago)

If you really, really needed to power a whole house, you could use one of those, but you need to turn off the main breaker and lock the door shut. If you have the foresight to get a male-to-male, you have the foresight to get an interconnect setup.

[–] chiliedogg@lemmy.world 8 points 1 day ago (2 children)

You can get a male-ended socket on the house for that exact scenario.

[–] ChaoticNeutralCzech@feddit.org 4 points 17 hours ago* (last edited 17 hours ago)

Don't forget a master switch between it and mains. Otherwise, line workers (and you) could get injured.

Bonus points if it auto-switches based on whether mains is available.

[–] Baggie@lemmy.zip 1 points 1 day ago

Oh that's so much smarter.

[–] expatriado@lemmy.world 6 points 1 day ago

i guess if you're got a bad breaker on your panel, you can load 2 circuits on one breaker with that thing, at least until the hardware store opens. you still get overcurrent protection.... but a very unlikely thing to need